Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Accuracy of Computerized Tomography for the Evaluation of Mandibular Sites Prior to Implant Placement
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 27 , Issue 6
November/December 2007

Pages 589-595


Accuracy of Computerized Tomography for the Evaluation of Mandibular Sites Prior to Implant Placement

Nicola Marco Sforza, DDS/Federico Franchini, DDS/Achille Lamma, DDS/Susanna Botticelli, DDS/Gino Ghigi, DDS, PhD


PMID: 18092453
DOI: 10.11607/prd.00.0776

The objective of the present study was to observe the effect of positioning of the mandible on the accuracy of cross-sectional images obtained by reformatting computerized tomographic (CT) scans. An additional aim was to evaluate the ability of a software program (DentalVox, Era Scientific) to reconstruct these measurements on the reformatted images, regardless of the positioning of the mandible, accurately and without distortion. The test was carried out by examining a partially edentulous dry human mandible with an acrylic radiologic template. Through the use of an acrylic glass support, the mandible was positioned at angles of 0, 10, 15, 20, and 30 degrees relative to the scanning gantry, and a series of CT scans was performed that provided five sets of axial images. Each set of original axial images was reformatted by the DentalVox software, used first in its basic function, which is typical of all software for axial CT measurement (control group), and again in its function of site-specific multiplanar reconstruction (test group). The results showed that the position of the mandible in relation to the CT gantry can influence the precision of the linear measurements. The error ranged from 2% to 51%. The DentalVox software allowed the reconstruction of cross-sectional images with very little distortion regardless of the mandibular position. (Int J Periodontics Restorative Dent 2007;27:589–595.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help